Narda PMM

Click Analyzer Narda PMM CA0010

Click Analyzer Narda PMM CA0010

The Next Generation Click Analyzer for Accurate and Reliable Measurements State-of-the-art technology for maximum precision: The innovative Click Anal CAZer CA0010 represents excellence in technology for the measurement of discontinuous disturbances (clicks). In combination with the EMI 9010F Receivers, ER8000 or ER9000 offers a complete and state-of-the-art solution for compliance with CISPR 14-1, IEC/EN55014-1 and CISPR 16-1-1, both in their current and future versions. Revolutionary architecture for greater efficiency: The innovative architecture of the CA0010 allows the integration of several advanced features in a single tool: Single-phase 16 A artificial network (LISN): allows you to perform measurements of conducted emissions and clicks with maximum precision. Switch counter with variable current threshold: Provides detailed analysis of disturbances generated by components such as relays and switches. Comprehensive and sophisticated calibrator: Generates the click sequenc..

EMI FFT receiver Narda PMM 9010F

EMI FFT receiver Narda PMM 9010F

State-of-the-art technology for electromagnetic compatibility The 9010F is one of the first receivers to be a significant step forward in the EMI field, offering a unique combination of advanced technology, exceptional performance and compliance with the strictest regulations. A beating heart of innovation: At the heart of the 9010F pulsates a state-of-the-art analog-to-digital conversion technology and a sophisticated data processing system. FFT frequency spectrum analysis provides unprecedented accuracy in identifying and measuring EMI emissions, enabling you to fully meet the requirements of CISPR 16-1-1. Real-time data for complete analysis: The FFT technology of the 9010F allows to obtain data in real time, eliminating the loss of information within the analyzed band. This means that users can monitor and analyze EMI emissions with unprecedented accuracy, quickly and confidently identifying noise sources. Guaranteed compliance, uncompromising reliability: The 9010F is equip..

EMI FFT receiver Narda PMM ER9000

EMI FFT receiver Narda PMM ER9000

The New Standard for Electromagnetic Emission Measurement Innovative design for maximum efficiency: The latest addition to the PMM receiver family, the ER9000, stands out for its avant-garde design that combines practicality and robustness. The practical and intuitive color touch-screen display offers a user-friendly interface, while the compact and robust chassis makes it extremely easy to handle. Perfect for laboratory and field use: Thanks to its portability and the included Li-Ion battery, the ER9000 is ideal for both laboratory and “in-field” use. Whether it’s routine testing in an EMC certification lab or on-site analysis, the ER9000 is the perfect tool for accurate electromagnetic emission measurement. Unprecedented speed and accuracy: The extremely fast scan time, in full compliance with the CISPR 16-1-1 standard, is guaranteed by an even more refined FFT technology. The ER9000 offers exceptional performance in terms of speed and accuracy, allowing you to optimize the mea..

EMI FFT receiver with integrated LISN Narda PMM ER8000

EMI FFT receiver with integrated LISN Narda PMM ER8000

The Compact and Powerful EMI Receiver for Fast and Accurate Measurements Flexibility and ease of use: The ER8000 receiver stands out for its exceptional compactness, making it ideal for use in tight spaces. Despite its compact size, it offers exceptional flexibility and ease of use, making it accessible even to less experienced users. High performance and regulatory compliance: The high performance of the ER8000 makes it the ideal tool for the precise measurement of conducted and radiated emissions. Full compliance with CISPR 16-1-1 ensures maximum reliability of the results obtained. Unprecedented measurement speed: Thanks to its state-of-the-art FFT architecture, the ER8000 boasts exceptionally fast analysis times: just 2 seconds in band B and 1 minute in bands C+D. This feature allows you to optimize the measurement process and increase productivity. Efficient front-end and versatile interface: The ER8000’s front-end features an efficient preselector that guarantees exceptio..

External units for 9010F and 9010/xxP Narda PMM 9030, 9060, 9180

External units for 9010F and 9010/xxP Narda PMM 9030, 9060, 9180

With the external units 9030, 9060 and 9180 you can easily extend the frequency range of your receiver up to a maximum of 18 GHz. Light and compact size, these units are equipped with a rechargeable Lio-Ion that allows you to work for hours without any interference. These external units are fully compliant with CISPR16-1-1 requirements and meet all commercial and military standards for EMC measurements. All external units are fully compatible with the receivers of the 9010 Series, 9010 and 9010F / xxP External drives for 9010F and 9010xx/P The 3 models available are: 9030-30MHz to 3GHz 9060 - 30 MHz to 6 GHz 9180 - 6 GHz to 18 GHz..

FFT receiver and ROD antenna Narda PMM FR-4003

FFT receiver and ROD antenna Narda PMM FR-4003

The FR4003 improves electric field measurement. It surpasses traditional rod antennas. It meets MIL-STD and CISPR specifications. It functions as a CISPR 16-1-1 receiver. It operates alone or with a PMM receiver. It meets standards in swept and FFT modes. It has analog signal output. Caution advised due to scattering. Internal receiver has preselectors, attenuators. Control via firmware or manual operation. Includes a tracking generator. Facilitates self-calibration and accuracy. Verifies grounding effectiveness. Functions as a field generator. Broadcasts internally generated signals. Includes controlling software. Operates on rechargeable Li-ion battery. Provides uninterrupted operation for several hours. Ensures measurements in undisturbed field. FFT field receiver and ROD antenna Main features of FR-4003: Antenna CISPR 12, CISPR 16, CISPR 25, MIL-STD, DO-160 fully compliant Internal full CISPR 16-1-1 receiver Operates both swept and gapless FFT modes Very fast measuring time..

Full/Pre-Compliant Receivers Narda PMM 9010/xxP

Full/Pre-Compliant Receivers Narda PMM 9010/xxP

Narda-PMM has developed new EMI / EMC receivers based on an innovative concept and a revolutionary approach to meet the needs of small and medium-sized laboratories that do not find it convenient to invest in a receiver conforming to the CISPR 16-1-1 also for radiated measurements. They are a perfect mix of full and Pre-Compliance to meet, in a perfect way, the requirements of practical tests, not excluding the possibility of future upgrades to 100% Full-Compliant to CISPR 16-1-1 up to 3, 6 or 18 GHz the simple addition of an external unit, 9030, 9060 or 9180, connected via fiber optic cable. The 9010 / xxP series receivers, are full compliance in accordance with the CISPR 16-1-1 in the band A and B and pre compliance in the next. Full/Pre compliance receivers Receivers 9010/xxp are available in the following versions: 9010/03P, 10 Hz – 300 MHz 9010/30P, 10 Hz – 3 GHz 9010/60P, 10 Hz – 6 GHz..

Isotropic E-Field RMS Sensor Narda PMM EP-333

Isotropic E-Field RMS Sensor Narda PMM EP-333

TheCalibration probe for the measurement of the electrical component of the electromagnetic field in the range 100 kHz - 3.6 GHz General Features: Measurements shown on the certificate: Correction factor in frequency Linearity Anisotropy Calibration E2PROM Specifications: Flatness (with correction disabled): 0.3 - 3500 MHz = 3 dB Flatness (with correction disabled): 3.5 - 3200 MHz = 1.5 dB Flatness (with correction disabled): 20 - 500 MHz = 0.75 dB Isotropicity: 0.8 dB (0.5 dB typical) H-field rejection > 20 dB Error at 20 ° C temperature: 60 °C + / - 0.1 dB, 0 °C: 20 °C - 0.05 dB / °C -20 °C 0 °C -0.15 dB / °C E 2 PROM internal calibration Dimensions: length 385 mm, 133 mm diameter Weight: 293 g..

Isotropic E-Field Sensor Narda PMM EP-105

Isotropic E-Field Sensor Narda PMM EP-105

The larda band probe EP-105 is a sensor suitable for measuring the electric field in the specific band between 100 kHz and 1000 MHz. Technical specifications: Range: 100kHz-1000MHz Flow rate: 0.05 - 50V / m Overload: > 100V / m Dynamics: > 60 dB Resolution: 0.01 V / m Sensitivity: 0.05 V / m Absolute Error @ 50MHz - 6V / m: ± 0.8 dB Flatness (10-300MHz): ± 0.5 dB Flatness (300kHz-1GHz): ± 1.0 dB Isotropicity: ± 0.8 dB Rejection magnetic field: > 20 dB..

Isotropic E-Field Sensor Narda PMM EP-201

Isotropic E-Field Sensor Narda PMM EP-201

Isotropic sensor for measuring the electrical component of the electromagnetic field in the range 60 MHz - 12 GHz General Features: Frequency Range: 60 MHz - 12 GHz Capacity: 3 - 500 V/m Overload: > 1000 V/m Dynamics: > 45 dB Resolution: 0.1 V/m Sensitivity: 8 V/m (instantaneous measurement with 10 Hz filter) and 3 V / m (RMS or AVG 30 sec with 10 Hz filter) Leaks in microwave equipment, coaxial cables, contacts shielded chamber doors, technical panels and research in physics, chemistry and biology laboratories Specifications: Internal microcontroller Flatness @ 40V/m: +/- 1.5 dB (150MHz - 9.25 GHz); +/- 3 dB (60MHz - 12GHz) Isotropicity @ 40V / m @ 200MHz: + / - 0.6 dB Rejection magnetic field: > 20 dB A/D conversion: internal-one converter for each of the three axes Internal E2PROM calibration Size: Ball diameter 3mm Quartz tube dimensions for descents: 180 mm long. 4 4 mm diameter Probe size: 300 mm long. diametro 18 mm diameter Weight: 85 g..

Isotropic E-Field Sensor Narda PMM EP-300

Isotropic E-Field Sensor Narda PMM EP-300

Probe for the measurement of the electrical component of the electromagnetic field in the range 100 kHz - 3 GHz General Features: Frequency range 100 kHz - 3 GHz Capacity: 0.1 - 300 V / m Overload > 600 V / m Dynamics > 66 dB Resolution: 0.01 V / m Sensitivity: 0.15 V / m Specifications: Absolute error @ 50 MHz and 20 V / m: + / - 0.8 dB Flatness (10-300 MHz): + / - 0.5 dB Flatness (3 MHz - 3 GHz): + / - 1.5 dB Isotropic response: + / - 0.8 dB (Typical + / - 0.5 dB @ 930 and 1800 MHz) H-field rejection:> 20 dB, 20 ° C: 60 ° C = + / - 0.1 dB Error at 0 ° C temperature: 20 ° C =- 0.05 dB / ° C -20 ° C 0 ° C =- 0:15 dB / ° C E 2 PROM internal calibration Dimensions: length 317 mm, 58 mm diameter Weight: 100 g..

Isotropic E-Field Sensor Narda PMM EP-301

Isotropic E-Field Sensor Narda PMM EP-301

The EP-301 larda band probe is a sensor suitable for measuring the electric field in the specific band between 100 kHz and 3 GHz Technical specifications: Range: 100kHz - 3GHz Flow rate: 0.1 - 1000 V/m Overload: > 1200 V/m Dynamics: > 60 dB Resolution: 0.1 V/m Sensitivity: 1 V/m Absolute Error @ 50MHz-20V / m: ± 0.8 dB Flatness (10-300MHz): ± 0.5 dB Flatness (3MHz-3MHz): ± 1.5 dB Isotropicity: ± 0.8 dB Rejection magnetic field: > 20 dB Temperature error: 0.05 db/°C..

Isotropic E-Field Sensor Narda PMM EP-330

Isotropic E-Field Sensor Narda PMM EP-330

Probe for the measurement of the electrical component of the electromagnetic field in the range 100 kHz - 3 GHz General Features: Frequency range 100 kHz - 3 GHz Capacity: 0.3 - 300 V / m Overload > 600 V / m Dynamics > 60 dB Resolution: 0.01 V / m Sensitivity: 0.3 V / m Specifications: Absolute error @ 50 MHz and 20 V / m: + / - 0.8 dB Flatness (10-300 MHz): + / - 0.5 dB Flatness (3 MHz - 3 GHz): + / - 1.5 dB Isotropic response: + / - 0.8 dB (Typical + / - 0.5 dB @ 930 and 1800 MHz) H-field rejection: > 20 dB, 20 ° C: 60 ° C = + / - 0.1 dB Error at 0 ° C temperature: 20 ° C =- 0.05 dB / ° C -20 ° C 0 ° C =- 0:15 dB / ° C E 2 PROM internal calibration Dimensions: length 317 mm, 58 mm diameter Weight: 100 g..

Isotropic E-Field Sensor Narda PMM EP-408

Isotropic E-Field Sensor Narda PMM EP-408

Probe for the measurement of the electrical component of the electromagnetic field in the range 1 MHz - 40 GHz General Features: Frequency Range 1 MHz - 40 GHz Capacity: 0.8 - 800 V/m Overload: > 1000 V/m Dynamics: > 60 dB Resolution: 0.01 V/m Sensitivity: 0.8 V/m Specifications: Absolute error @ 200 MHz and 6 V / m: + / - 0.8 dB Flatness (1 MHz - 1 GHz): + / - 1.5 dB Flatness (1 - 3 GHz): + / - 2 dB Flatness (3 - 18 GHz): + / - 2.5 dB Flatness (18 - 26.5 GHz): + / - 3 dB Flatness (26.5 - 40 GHz): + / - 4 dB Isotropicity @ 200 MHz: + / - 0.8 dB (Typical + / - 0.5 dB @ 930 and 1800 MHz) H-field rejection:> 20 dB Error in temperature: 0.02 dB / °C E 2 PROM internal calibration Dimensions: length 317 mm, 52 mm diameter Weight: 90 g..

Showing 1 to 15 of 26 (2 Pages)